Arko technical sheet
Single-leaf model sheet: construction, section and declared data. The double-leaf configuration must be checked separately for Arko 2.
AERRE / Technical studio
Model data, construction sections and documents. A working reference for designers, dealers and installers, from door selection to long-term care.
Talk to technical support01 / DOWNLOAD
The right document for each stage.
7 documents available
Single-leaf model sheet: construction, section and declared data. The double-leaf configuration must be checked separately for Arko 2.
Components, construction section and declared burglary resistance class. This sheet is not an original test report.
Two pages of presentation and components. Fire classification and its field of application must be verified for the project.
Page 47 of the historical original Aerre price list. Diagram for a lugged subframe and masonry: confirm applicability to the specified door and substrate.
Page 48 of the historical original price list: panels for a standard H 2100 leaf. Arko, Wall-Zip and symmetrical double-leaf doors are excluded from the table.
Pages 23–24 of the supplied 2026 technical and commercial price list: opening, frame, leaf and handover checks. General guidance requiring model-specific confirmation.
Pages 37–38 of the supplied 2026 technical and commercial price list: daily use and periodic checks. Request the specific instructions for the door, lock and cladding.
The model sheets are manufacturer PDFs. Documents labelled as excerpts preserve the original pages from the supplied price lists; they are not new certificates or model-specific manuals.
02 / DECLARED DATA
A view across the collection.
| Model | Burglary resistance | Wind | Water | Air | Acoustics | Transmittance |
|---|---|---|---|---|---|---|
| Sikura | 3 | C3 | 2A | 2 | 32dB | 1,82 W/m2K |
| Stylo | 4 | A3 | 3A | 2 | 30 dB | 2,03 W/m²K |
| Stylo 2 | 4 | A3 | 3A | 2 | 30 dB | 2,03 W/m²K |
| Stylo Plus | 4 | C3 | 2A | 2 | 41dB | 1,29 W/m2K |
| Stylo 2 Plus | 4 | C4 | 2A | 2 | 42 dB | 1,34 W/m²K |
| Arko | Class 4 | Class C4 | Class 3A | Class 3 | 39 dB | 1,58 W/m²K |
| Arko 2 | Class 4 | Class C4 | Class 3A | Class 3 | 39 dB | 1,58 W/m²K |
| Liberty | On request | On request | On request | On request | On request | On request |
| Liberty 2 | On request | On request | On request | On request | On request | On request |
| Wall-Zip | On request | On request | On request | On request | On request | On request |
| Wall-Zip 2 | On request | On request | On request | On request | On request | On request |
| Biliko | On request | On request | On request | On request | On request | On request |
| Armor | Class 5 | On request | On request | On request | On request | On request |
| Fire-Blok | RC 4 | On request | On request | On request | On request | On request |
Units and classifications follow the sources. “On request” means a value was not verified on the consulted pages, not a zero value. A performance value relates to the model and configuration covered by its documentation.
Presentation sheets do not replace test reports, classifications or declarations of performance. The manufacturer declares EI₂ 60 for Fire-Blok: request the relevant document and check the dimensions, hardware and installation conditions of the selected configuration.
Request performance documentation03 / CONSTRUCTION
The frame and subframe connect the door structure to the wall. The Arko, Armor and Fire-Blok sheets describe a PVC-coated 20/10 galvanised steel frame and a 20/10 galvanised steel subframe with 8 integral anti-tear loops.
The three sheets show construction sections without numerical profile dimensions. Section sizes must not be inferred from image scale. The Sikura product page declares a 15/10 sheet-steel frame; this specification must not be extended to the range.
Clear opening, overall size, threshold, opening direction and position within the reveal are defined by the survey and model. Request the appropriate section before preparing the opening.

04 / CLADDINGS
Reference dimensions. Read alongside the drawing.
Page 48 of the historical original price list lists the following panels for a standard H 2100 leaf. All dimensions in this table are in millimetres; the outer and inner panels have different sizes.
| Leaf | Outer panel | Inner panel | Thickness |
|---|---|---|---|
| 800 | 815 × 2100 | 845 × 2117 | 7 |
| 850 | 865 × 2100 | 895 × 2117 | 7 |
| 900 | 915 × 2100 | 945 × 2117 | 7 |
| Secondary leaf 300 | 280 × 2100 | 280 × 2117 | 7 |
View the original page with drilling dimensions and legend ↗
05 / SUPPORT DOCUMENTATION
The original subframe installation page shows a lugged system, masonry, spacers and threshold level. The substrate and intended fixing method must match the applicable documentation.
Read the original document ↗The supplied technical and commercial price list includes checks on the opening, frame and locking system. Fixing selection, adjustments and handover require the model instructions and a site-specific assessment.
View the available guidance ↗The care pages in the supplied document cover daily use, cleaning and checks. Cladding material, locks and devices may require specific procedures: consult their respective manuals.
Read use and maintenance ↗Provide the model, year or order reference, lock type and photographs of the configuration. For installation, component replacement and adjustment, request the relevant manual without applying instructions from other models by analogy.
Request the documentElectronic locks, power supply, wiring and emergency opening depend on the device. The Smart manual advertised in the previous archive is not among the verified PDFs: request the instructions for the installed system.
Request the document06 / TECHNICAL SUPPORT
Start with the details of your entrance.