AERRE / TECHNICAL STUDIO

Design well.
Down to the detail.

A technical resource for understanding the models, preparing your project and requesting installation and maintenance documents.

01

Every model.
Its performance.

Compare the performance declared on the manufacturer’s pages. N.D. means a value has not been declared, not that performance is zero.

ArkoPerformance and documents
Declared performance for this model
Wind resistanceClass C4
WatertightnessClass 3A
Air permeabilityClass 3
Acoustic insulation39 dB
Thermal transmittance1,58 W/m²K
Burglar resistanceClass 4
Arko 2Performance and documents
Declared performance for this model
Wind resistanceClass C4
WatertightnessClass 3A
Air permeabilityClass 3
Acoustic insulation39 dB
Thermal transmittance1,58 W/m²K
Burglar resistanceClass 4
ArmorPerformance and documents
Declared performance for this model
Wind resistanceNot declared
WatertightnessNot declared
Air permeabilityNot declared
Acoustic insulationNot declared
Thermal transmittanceNot declared
Burglar resistanceClass 5
BilikoPerformance and documents
Declared performance for this model
Wind resistanceNot declared
WatertightnessNot declared
Air permeabilityNot declared
Acoustic insulationNot declared
Thermal transmittanceNot declared
Burglar resistanceTo be checked in project documentation
Fire-BlokPerformance and documents
Declared performance for this model
Wind resistanceNot declared
WatertightnessNot declared
Air permeabilityNot declared
Acoustic insulationNot declared
Thermal transmittanceNot declared
Burglar resistanceRC 4
Fire resistanceEI₂ 60 minutes
LibertyPerformance and documents
Declared performance for this model
Wind resistanceNot declared
WatertightnessNot declared
Air permeabilityNot declared
Acoustic insulationNot declared
Thermal transmittanceNot declared
Burglar resistanceNot declared
Liberty 2Performance and documents
Declared performance for this model
Wind resistanceNot declared
WatertightnessNot declared
Air permeabilityNot declared
Acoustic insulationNot declared
Thermal transmittanceNot declared
Burglar resistanceNot declared
SikuraPerformance and documents
Declared performance for this model
Wind resistanceC3
Watertightness2A
Air permeability2
Acoustic insulation32dB
Thermal transmittance1,82 W/m2K
Burglar resistance3
Stylo PlusPerformance and documents
Declared performance for this model
Wind resistanceC3
Watertightness2A
Air permeability2
Acoustic insulation41dB
Thermal transmittance1,29 W/m2K
Burglar resistance4
StyloPerformance and documents
Declared performance for this model
Wind resistanceA3
Watertightness3A
Air permeability2
Acoustic insulation30 dB
Thermal transmittance2,03 W/m²K
Burglar resistance4
Stylo 2Performance and documents
Declared performance for this model
Wind resistanceA3
Watertightness3A
Air permeability2
Acoustic insulation30 dB
Thermal transmittance2,03 W/m²K
Burglar resistance4
Stylo 2 PlusPerformance and documents
Declared performance for this model
Wind resistanceC4
Watertightness2A
Air permeability2
Acoustic insulation42 dB
Thermal transmittance1,34 W/m²K
Burglar resistance4
Wall-ZipPerformance and documents
Declared performance for this model
Wind resistanceNot declared
WatertightnessNot declared
Air permeabilityNot declared
Acoustic insulationNot declared
Thermal transmittanceNot declared
Burglar resistanceNot declared
Wall-Zip 2Performance and documents
Declared performance for this model
Wind resistanceNot declared
WatertightnessNot declared
Air permeabilityNot declared
Acoustic insulationNot declared
Thermal transmittanceNot declared
Burglar resistanceNot declared
02

Measure.
Before choosing.

Opening survey: width, height and clear openingW / vano murarioH / altezza vanoL / luce di passaggioIndicative diagram, not to scale

The survey your project needs

Record opening width and height, finished floor level, wall thickness and opening direction. Distinguish the structural opening, overall frame dimensions and clear passage.

Working dimensions and cladding sizes depend on model and order. They cannot be taken from photographs or a standard size: request the approved drawing.

  • Internal and external panels: width, height, thickness
  • Rebates, edges, machining and hardware holes
  • Exposure, material and cladding compatibility
Request your model’s dimensions
03

One structure.
Every connection.

Sezione tecnica originale Arko: anta, telaio e falso telaio
Original section from the Arko sheet. Model-specific reference; no numerical dimensions are published.
01 / ANTA

Sheet steel and reinforcement

For Arko, the sheet specifies a 15/10 galvanised steel leaf and double omega reinforcement from a single 8/10 sheet. Read the structure alongside the model’s configuration.

02 / TELAIO

The connection to the leaf

For Arko, a PVC-coated 20/10 galvanised steel frame and 70 mm hinges adjustable in three positions. These details do not automatically apply to other models.

03 / FALSO TELAIO

The interface with the wall

The Arko sheet specifies eight anti-tear U-bolts formed from the 20/10 profile. Define anchors, support and installation sequence using the model’s instructions and installation design.

04

Performance.
With documents.

CE marking and Declaration of Performance

CE marking relates to the product and its scope. Request the Declaration of Performance and documentation relevant to the model, configuration and order. Commercial sheets do not replace certificates or test reports.

Request certificates and DoP

Arko, Armor and Fire-Blok sheets are available. Request Declarations of Performance, certificates and other manuals for your specific project.

05

Installation.
Part of the project.

A checking process to prepare the work. Working procedures, anchors and adjustments must follow the model’s manual and be carried out by qualified personnel.

Indicative checking diagrams, not to scale and not working drawings.

01

Survey and support check

Check the opening, finished floor, opening direction and wall compatibility. Confirm dimensions against the order drawing before installation.

02

Subframe installation

Check subframe identification, position, plumb, level and diagonals. The anchoring system and execution must follow the specific instructions and installation design.

03

Frame and leaf assembly

Check that components match the model and order. Follow the manual’s sequence and check support, fastening and continuity of specified joints.

04

Adjustment and functional checks

Check leaf movement, clearances, closing, lock, seals and hardware. For a fire-resistant door, also verify the devices and requirements of its manual.

05

Final checks and handover

Document the final inspection and hand over instructions, keys, model references and applicable documents. Explain operation and maintenance to the user.

Before starting work

Request the door and subframe installation manuals, approved drawing, component list and support requirements. This guide does not replace the manufacturer’s working instructions.

Request installation instructions
06

Care for it.
Over time.

Daily use

Use the lock and hardware according to the supplied instructions. Do not force the leaf or mechanisms; report changes in movement or closing.

Cladding cleaning

Follow the material and finish instructions. Before using a product, check compatibility: wood, leather, stone, metals and painted surfaces need different care.

Lock and components

Use only lubricants, adjustments and replacements specified by the component manufacturer. Do not apply generic products without checking suitability.

Seals and closing

Visually check seal integrity, contact and cleanliness. If the door drags, does not close or shows different clearances, request a technical check.

Service and replacements

Provide the model, order reference, problem and photographs. Keep documents and instructions: they help identify the correct components.

AERRE / PRIVACY

Your preferences.

This site does not activate analytics or advertising trackers. A project you choose to save stays in your browser for 30 days. You can delete it at any time.

Leggi l’informativa cookie ↗
Aerre cladding detail